HI,欢迎来到深圳市奈良机工贸易有限公司网站
全国热线:18819066842

热门搜索: 协和滚筒 TOYO 日本共和 日本安川

品质保障

用心服务

官方正品

日本工业品 诚信 公正 效率

栏目导航

navigation

日本CCS

您的当前位置:网站首页 > 产品中心 > 日本CCS

日本CCS电源PD3-5024-4-SI(A)
发布时间:2024-04-28

日本CCS电源PD3-5024-4-SI(A)

日本CCS电源PD3-5024-4-SI(A)

  • Standard Product

This Digital Control Unit can be used for LED Light Units with an input voltage of 24 V within a total power consumption of 46 W.
Connection with the HLV3/HLV2-series Spot Lights is also available.
This Control Unit operates on a 100 to 240 VAC input and measures 197 x 82.6 x 120 mm (width x depth x height). External control through EIA-485 communications.

    

Product Details

DimensionsW 197 mm x D 82.6 mm x H 120 mm
Applicable Light Unit (output ratings)Light Units with 24 VDC input, HLV3/HLV2 series (Spot Light)
Total for 4 channels: 46 W
Number of channels4 channels
Lighting methodConstant/Strobe lighting
Drive method24V LIGHT connectors: Constant-voltage system,
HLV LIGHT connectors: Constant-current system
Intensity control method24V LIGHT connectors: PWM control and lighting time control,
HLV LIGHT connectors: Variable-current control
PWM frequency125kHz
Input voltage100 to 240 VAC (+10% -15%)
Frequency50/60 Hz
Power consumption70 VA
Output voltage24VDC
Output currentTotal for 4 channels: 1.91 A
Inrush current15 A (at 100 VAC), 30 A (at 200 VAC) from a cold start
Intensity controlManual: 256-step using the front setting switch
External: Command input via EIA-485 communication
Error detection displayDigital display on the front-panel;
OCP: Overcurrent error, EFN: Fan Stop Error,
and EID: ID error (HLV3/HLV2-series Spot Lights only)
Error detection outputCommand sent when overcurrent output is detected.
Over current protectionOperates at 107% of rated output current or higher. Reset by pressing operation setting switch for at least 1 second or by cycling the power supply.
*Do not intentionally short-circuit the positive and negative output terminals.
Output connectorSMP-03V-BC x 8
External control connectorTrigger input: MIL connector (MIL-C-83503 compliant), 10 pins
For setting the light intensity/mode: e-CON connector, 3 pins
Conformed standardsCE, UKCA、RoHS
Operating temperature and humidityTemperature: 0 to 40°C, Humidity: 20 to 85%RH (no condensation)
Storage temperature and humidityTemperature: -20 to 60°C, Humidity: 20 to 85%RH (no condensation)
Cooling methodForced cooling
Weight1,200 g
MaterialAluminium, ABS
Accessories2m long 3-pin power cord with ground terminal x1
Base Brackets x1 set
Instruction Guide x1
Program[Sample Program]
Sample programs are available. See the Options tab.