日本韦尔科Welco管泵WPM1-P1AB-RP
发布时间:2024-05-27

日本韦尔科Welco管泵WPM1-P1AB-RP

WPM1 Peristaltic pump series

WPM1

Super Engineering Plastics

Super engineering plastic, having excellent corrosion resistance, are used for the main tube parts and enable the pumps to be used with strong acids, strong alkalis,and chemical solutions that erode general-purpose plastic. The heat resistance is also excellent, use in various environments can be supported.

Fluid temperature5℃ to 50℃
Material (Pump parts)PSU (Cassette/Rotor/Base), POM (Roller,etc)
AutoclaveNot Available

WPM2 Peristaltic pump series

WPM2

Compatible with autoclave sterilization (WPM2 model)

All parts of the WPM2 pump cassette are made of super engineering plastic  that has excellent heat resistance. Autoclave sterilization can now be performed on industrial-use compact-size peristaltic pumps. Pump operation supports liquid solution temperatures of up to 80℃.

Fluid temperature5℃ to 50℃
Material (Pump parts)PSU (All parts)
AutoclaveAutoclave condition: 0.1MPa, 121℃, 20min  Only the Pump parts.

Note: Autoclave sterilization is assumed to be performed under the conditions of 0.1MPa (121℃) for 20 minutes. Number of autoclave is supposed less than 30 times.(except pump tube) If the actual conditions will exceed these values, be sure to perform a confirmatory evaluation. Even when using tubing that can be autoclaved, performing the autoclave sterilization process while the tubing is fitted to the pump may cause the flow rate to change. If this is a concern, remove the tubing and sterilize separately.

General specifications

Model nameWPM1 WPM2
Recommended installation height2 meter ( 6.8 ft.) max (Water suction)
Liquid temperature range0 to 50°C (32°F to 122°F)5-80°C (32 to 176°F)
Environment temperature range0-50°C (32 to 122°F) (Note: Freezing must be prevented.)
Ambient humidity range20-85% RH (Note: Condensation must be prevented.)
Max. Discharge pressure90kPa (Pharmed BPT) Silicone 80kPa or less
Max. Suction pressure-90kPa (Pharmed BPT) Silicone -80kPa or less
AutoclaveNot AvailableAutoclave condition: 0.1MPa, 121°C,
20min  Only the Pump parts.
Material (Pump parts)PSU (Cassette/Rotor/Base)
POM (Roller,etc)
PSU (All parts)
Certifications & Approvalswpm_guide06_img05.jpg


*UL: Except CA type
using screws (unit: mm)

using screws

one-touch mounting (unit: mm)

one-touch mounting