日本TACO/AZBIL调压阀RVD-520YF-HLTT
发布时间:2024-07-10
日本TACO/AZBIL调压阀RVD-520YF-HLTT
R31 SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
RELIEF | Relieving and Non-relieving |
ADJUSTMENT | Snap lock knob type (one touch lock) |
RK-1206 SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
MAXIMUM INLET PRESSURE | 1.0MPa | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
ADJUSTING PRESSURE RANGE | •0.02 ~ 0.8MPa •0.01 ~ 0.4MPa | |
RELIEF | Relieving | |
PIPE SIZE | Inlet port (common) | Rc3/4 at both sides |
Outlet port | Rc1/2 at each regulator | |
Gauge port | Rc1/8 at each regulator |
NRV-300, 200 SERIES
SPECIFICATIONS
SERIES | NRV-300 | NRV-200 |
FLUID | Filtered Compressed Air | |
MAXIMUM INLET PRESSURE* | 1.0MPa | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
OPERATION | Directly operated by spring | |
ADJUSTING PRESSURE RANGE | •0.02 ~ 0.8MPa (Std.) •0.01 ~ 0.3MPa •0.01 ~ 0.1MPa •0.1 ~ 1.6MPa * | |
RELIEF | Relieving | Non-relieving |
* Max Inlet pressure: 2.8MPa for units of ~1.6MPa range.
* 0.1~1.6MPa range is available for units of pipe size of 1/4,3/8 and 1/2.
BASIC MODEL NOs. & OTHERS
Pipe Size | MODEL NUMBER | Gauge Port | Mass(kg) | |
Relieving | Non-relieving | |||
Rc1/4 | NRV-302 | NRV-202 | Rc1/8 (2 places) | 1.2 |
Rc3/8 | NRV-303 | NRV-203 | ||
Rc1/2 | NRV-304 | NRV-204 | 1.4 | |
Rc3/4 | NRV-306 | NRV-206 | 2.9 | |
Rc1 | NRV-310 | NRV-210 | 2.7 |
NRV-400 SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Integral pilot operated type (Internal pilot type) |
ADJUSTING PRESSURE RANGE | •0.02 ~ 0.7MPa (Std.) •0.01 ~ 0.4MPa •0.01 ~ 0.2MPa •0.1 ~ 1.6MPa* |
RELIEF | Relieving and Non-relieving |
* Max Inlet pressure is 2.8MPa in case of units of 0.1~1.6MPa range.
BASIC MODEL NOs. & OTHERS
Pipe Size | MODEL NUMBER | Adjusting Pressure Range | Gauge Port | Mass (kg) |
Rc1/2 | NRV-404 | 0.2 ~ 0.7Mpa | Rc1/8 (2 places) | 1.7 |
NRV-404K4 | 0.01 ~ 0.4Mpa | |||
NRV-404K2 | 0.01 ~ 0.2Mpa | |||
Rc3/4 | NRV-406 | 0.02 ~ 0.7Mpa | 3.1 | |
NRV-406K4 | 0.01 ~ 0.4Mpa | |||
Rc1 | NRV-410 | 0.02 ~ 0.7Mpa | 3.0 | |
NRV-410K4 | 0.01 ~ 0.4Mpa |
RVD-400YF SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Integral pilot operated type (Internal pilot type) |
ADJUSTING PRESSURE RANGE | 0.02 ~ 0.8MPa |
RELIEF | Relieving and Non-relieving |
NRV-500 SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Remote controlled type (External pilot operated type) |
OUTLET PRESSURE ADJUSTING RANGE | 0.02 ~ 0.8MPa (within the limits of pilot regulator) |
RELIEF | Relieving and Non-relieving |
RVD-500YF SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Remote controlled type (External pilot type) |
ADJUSTING PRESSURE RANGE | 0.02 ~ 0.8MPa |
RELIEF | Relieving and Non-relieving |
R50 SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air Use air filter with 5μm element. |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Integral Feed-back pilot operated (Internal Pilot type) |
ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa |
RELIEF | High-relieving |
STANDARD EQUIPPED PART | Bracket and Adapter for connecting pressure gauge |
R50-R SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Feed-Back Pilot Remote control type (External Pilot operated type) |
ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa Depends on adjusting pressure range of pilot regulator. |
RELIEF | High-relieving |
EQUIPPED PART WITH STANDARD MODEL | Bracket and Adapter for connecting pressure gauge |
R50-M SERIES
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
OPERATION | Remote controlled type (External Pilot operated type) |
ADJUSTING PRESSURE RANGE | 0.05 ~ 0.8MPa Depends on adjusting pressure range of pilot regulator. |
RELIEF | High-relieving |
EQUIPPED PART WITH STANDARD MODEL | Bracket and Adapter for connecting pressure gauge |
NRV-802 SERIES
SPECIFICATIONS
MODEL NUMBER | NRV-802 | NRV-802K16 | NRV-802K4 | NRV-802K2 |
PIPE SIZE | Rc1/4 | |||
FLUID | Filtered Clean Air (Use 25μm filter element) | |||
MAXIMUM INLET PRESSURE* | 1.0MPa | |||
AMBIENT TEMPERATURE | 5 ~ 60°C | |||
ADJUSTING PRESSURE RANGE | 0.02 ~ 0.7MPa | 0.1 ~ 1.6MPa | 0.01 ~ 0.4MPa | 0.01 ~ 0.2MPa |
OPERATION | Directly operated and constant bleed type | |||
RELIEF | Relieving type | |||
GAUGE PORT | Rc1/8 | |||
MASS (kg) | 0.84 |
* Max. inlet pressure is 2.8MPa in case of 0.1~1.6MPa range (K16).
NRV-802D SERIES
SPECIFICATIONS
MODEL NUMBER | NRV-802D |
PIPE SIZE | Rc1/4 (IN, OUT Port) |
FLUID | Filtered Clean Air (w/5μm element) |
MAXIMUM INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
FEED BACK PORT | Rc 1/8 |
MASS (kg) | 0.95 |
* For panel mount, add “P” at the end of model no.
Note: This regulator is used only as pilot regulator. In this case, master regulator recommended is R50-M series high relieving type.