日本ORION好利旺CBF组合干泵CBF2525-VV-01B/CBF2525-BB-01B
发布时间:2024-08-17

日本ORION好利旺CBF组合干泵CBF2525-VV-01B/CBF2525-BB-01B


CBF Combination Dry PumpSafety Enhanced Design・Low Noise ・ Long Life ・ Environmentally Friendly

CBF1515 / CBF2525 / CBF4040

  • Continuous Operating Vacuum

  • Recomm. 60 kPa or less
    (V Type)

  • Continuous Operating Pressure

  • Recomm. 60 kPa or less
    (B Type)

  • Continuous Combined Operating Vacuum & Pressure

  • Total Combined Vacuum & Pressure 60 kPa or less
    (VBVB Type)

  • Flow Rate

  • 280 to 685 L/min (60 Hz)

  • Safe and Environmentally Conscious
    CE Marking Certified

  • Quiet Operation
    Noise level reduced by 3 dB (compared with conventional models)

  • Long Life
    Increased 30% with newly developed vane blade material. (Compared with conventional models).

CBF4040
CBF4040-VB

Specifications

Model CBF1515-VB-01BVB-04B ※3VBVB-01BVBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (V,B): 235/280
Pump 2 (V,B):235/280
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)60-
Continuous Combined Operating Vaccum & Pressure (VB)kPa-Recom. ※5, Max. ※6
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz)A3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
Noise Level (50/60 Hz) ※4dB62/6365/66
MotorkW0.75
Masskg37
Model CBF1515-VV-01BBB-01B
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (B): 235/280
Pump 2 (B):235/280
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)-60
Continuous Combined Operating Vaccum & Pressure (VB)kPa-
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz)A3.8/3.4, 3.4, 3.4
Noise Level (50/60 Hz) ※4dB61/6265/66
MotorkW0.75
Masskg37


Model CBF2525-VB-01BVB-04B ※3VBVB-01BVBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (V,B): 405/480
Pump 2 (V,B):405/480
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)60-
Continuous Combined Operating Vaccum & Pressure (VB)kPa-Recom. ※5, Max. ※6
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz)A6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
Noise Level (50/60 Hz) ※4dB64/6767/70
MotorkW1.5
Masskg52
Model CBF2525-VV-01BBB-01B
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (B): 405/480
Pump 2 (B):405/480
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)-60
Continuous Combined Operating Vaccum & Pressure (VB)kPa-
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz)A6.8/6.4, 6.0, 6.0
Noise Level (50/60 Hz) ※4dB63/6667/70
MotorkW1.5
Masskg52


Model CBF4040-VB-01BVB-04B ※3VBVB-01BVBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1(V,B): 575/685
Pump 2 (V,B):575/685
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)60-
Continuous Combined Operating Vaccum & Pressure (VB)kPa-Recom. ※5, Max. ※6
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz)A10.6/
9.4, 9.2, 9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
10.6/
9.4、9.2、9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
Noise Level (50/60 Hz) ※4dB68/7069/71
MotorkW2.2
Masskg67
Model CBF4040-VV-01BBB-01B
Designed Pumping Capacity (50/60 Hz) ※1L/minPump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1 (B): 575/685
Pump 2 (B):575/685
Continuous Operating Vacuum (V) ※2kPa (max.)60-
Continuous Operating Pressure (B) ※2kPa (max.)-60
Continuous Combined Operating Vaccum & Pressure (VB)kPa-
Piping Connection SizeRc 3/4
Voltage (50/60 Hz)V3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz)A10.6/9.4, 9.2, 9.2
Noise Level (50/60 Hz) ※4dB67/6971/73
MotorkW2.2
Masskg67
  1. Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.

  2. Operable range of vacuum (pressure).

  3. "04" models are special order items.

  4. Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.

  5. Recommended range of combined vacuum and pump pressures: 60 or lower.

  6. Maximum vacuum/pressure per pump can be any combination of the following (vacuum/pressure): 55/20, 55/30, 40/40, 35/50. The maximum vacuum/pressure of the dry pump indicates the maximum sustainable vacuum/pressure. Do not operate the pump beyond this maximum value. Doing so can reduce the lifespan of the pump and may result in breakdown or an accident.

  • Please consult with your dealer regarding operation in extremely dry environments, as doing so may lead to pump damage.

  • Allowable intermittent power supply voltage fluctuation range is +10% of the specified voltage, allowable sustained supply voltage fluctuation range is +5% of the specified voltage.

  • When using other than the ORION standard motor, follow the electrical guidelines printed on the nameplate of the motor used.

  • Please install an overload protection device (such as a thermal relay).

Scroll

  • If detailed specifications are required, please Contact ORIONc to request a specifications sheet.

联系我们